acdc

Dell Inc. PowerEdge R815 x86_64

Back to Nodes
Processor

64 Cores

AMD Opteron(TM) Processor 6276
Memory Slots

32 / 32 Used

64 GB DDR3 @ 1333 MT/s
Storage Drives

3 Disks

0 SSD | 3 HDD
PCI Express Slots

0 / 6 In Use

6 Available Slots
Processor Details
Model NameAMD Opteron(TM) Processor 6276
Architecturex86_64
Sockets4
Logical Cores64
Threads / Core2
Max FrequencyN/A MHz
L3 Cache48 MiB (8 instances)
VirtualizationAMD-V
System & BIOS Information
ManufacturerDell Inc.
Product NamePowerEdge R815
VersionNot Specified
Serial Number1WS0TS1
UUID4c4c4544-0057-5310-8030-b1c04f545331
Wake-up TypePower Switch
SKU NumberNot Specified
FamilyNot Specified
Physical Memory Modules
32 / 32 Slots Populated
Slot / Locator Status Capacity Speed Type Manufacturer Part Number
DIMM_A1 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_A2 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_A3 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_A4 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_A5 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_A6 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_A7 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_A8 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_B1 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_B2 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_B3 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_B4 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_B5 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_B6 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_B7 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_B8 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_C1 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_C2 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_C3 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_C4 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_C5 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_C6 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_C7 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_C8 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_D1 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_D2 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_D3 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_D4 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_D5 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_D6 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_D7 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
DIMM_D8 Installed 2 GiB 1333 MT/s DDR3 80AD000080AD HMT325U7BFR8A-H9
Disk Drives
Device Name Capacity Drive Model Type
sda 272.3G PERC H700 HDD
sdb 558.4G PERC H700 HDD
sdc 558.4G PERC H700 HDD
Block Hierarchy Tree
sda   272.3G   PERC H700   disk
└─sda1   272.2G   1   part
sdb   558.4G   PERC H700   disk
├─sdb1   1G   1   part
├─sdb2   2G   1   part
└─sdb3   555.3G   1   part
└─ubuntu--vg-ubuntu--lv   100G   1   lvm
sdc   558.4G   PERC H700   disk
└─sdc1   558.4G   1   part
sdd   200G   VIRTUAL-DISK   disk
sde   5G   VIRTUAL-DISK   disk
sdf   100G   VIRTUAL-DISK   disk
sdg   5G   VIRTUAL-DISK   disk
sdh   8G   VIRTUAL-DISK   disk
sdi   8G   VIRTUAL-DISK   disk
sdj   10G   VIRTUAL-DISK   disk
sdk   8G   VIRTUAL-DISK   disk
sdl   8G   VIRTUAL-DISK   disk
sdm   50G   VIRTUAL-DISK   disk
sdn   8G   VIRTUAL-DISK   disk
sr0   1024M   DVD+-RW DS-8A5SH   rom
Graphics & Video Controllers
VGA compatible controller [0300]: Matrox Electronics Systems Ltd. MGA G200eW WPCM450 [102b:0532] (rev 0a) (prog-if 00 [VGA controller])
Bus Address: 0000:0a:03.0
Detected
Physical Network Adapters
Broadcom Inc. and subsidiaries NetXtreme II BCM5709 Gigabit Ethernet [14e4:1639] (rev 20)
Bus Addresses (4 Ports / Functions): 0000:01:00.0 0000:01:00.1 0000:02:00.0 0000:02:00.1
4 Ports
USB Network & Peripheral Devices
  • Bus 001 Device 001: ID 1d6b:0001 Linux 6.8.0-136-generic ohci_hcd OHCI PCI host controller
  • Bus 002 Device 001: ID 1d6b:0002 Linux 6.8.0-136-generic ehci_hcd EHCI Host Controller
  • Bus 003 Device 001: ID 1d6b:0002 Linux 6.8.0-136-generic ehci_hcd EHCI Host Controller
  • Bus 003 Device 002: ID 0424:2514
  • Bus 004 Device 001: ID 1d6b:0001 Linux 6.8.0-136-generic ohci_hcd OHCI PCI host controller
  • Bus 005 Device 001: ID 1d6b:0001 Linux 6.8.0-136-generic ohci_hcd OHCI PCI host controller
  • Bus 006 Device 001: ID 1d6b:0001 Linux 6.8.0-136-generic ohci_hcd OHCI PCI host controller
PCI Express Expansion Slots
0 / 6 Slots In Use
Slot Designation Slot Specification Status Bus Address Linked Device plugged into Slot
PCI1 PCI Express 2 x8 Available N/A No Device Linked
PCI2 PCI Express 2 x4 Available N/A No Device Linked
PCI3 PCI Express 2 x8 Available N/A No Device Linked
PCI4 PCI Express 2 x8 Available N/A No Device Linked
PCI5 PCI Express 2 x8 Available N/A No Device Linked
PCI6 PCI Express 2 x8 Available N/A No Device Linked
Power Supply & BMC FRU Details
Builtin FRU Device (ID 0)
Board Mfg DELL
Board Product PowerEdge R815
Board Serial CN747511BU0163
Board Part Number 0272WFA00
Product Manufacturer DELL
Product Version 02
Product Serial 1WS0TS1
PS 1 (ID 2)
Board Mfg DELL
Board Product PWR SPLY,1100W,RDNT
Board Serial CN716151920DA0
Board Part Number 0TCVRRA01
PS 2 (ID 3)
Board Mfg DELL
Board Product PWR SPLY,1100W,RDNT
Board Serial CN716151920DA1
Board Part Number 0TCVRRA01
Storage (ID 1)
Board Mfg DELL
Board Product FRU256,DELL P/N 03K345A00
Board Serial CN137401C203J3
Board Part Number 0XXFVXA05
Back Plane (ID 4)
Board Mfg DELL
Board Product FRU256,DELL P/N 03K345A00
Board Serial CN645351AIN3X0
Board Part Number 0WR7PPA00
CPU Planar (ID 5)
Board Mfg DELL
Board Product PowerEdge R815
Board Serial CN747511AT0046
Board Part Number 0FP13TA02
Raw Tool Output Logs
# dmidecode 3.7
Getting SMBIOS data from sysfs.
SMBIOS 2.6 present.
103 structures occupying 6764 bytes.
Table at 0x7B15A020.

Handle 0xDA00, DMI type 218, 11 bytes
Dell Token Interface
	Command I/O Address: 0x00b0
	Command I/O Code: 0x17
	Supported Command Classes Bitmap: 0x00200e00

Handle 0x0000, DMI type 0, 24 bytes
Platform Firmware Information
	Vendor: Dell Inc.
	Version: 2.3.0
	Release Date: 10/18/2011
	Address: 0xF0000
	Runtime Size: 64 KiB
	ROM Size: 4 MiB
	Characteristics:
		ISA is supported
		PCI is supported
		PNP is supported
		Firmware is upgradeable
		Firmware shadowing is allowed
		Boot from CD is supported
		Selectable boot is supported
		EDD is supported
		Japanese floppy for Toshiba 1.2 MB is supported (int 13h)
		5.25"/360 kB floppy services are supported (int 13h)
		5.25"/1.2 MB floppy services are supported (int 13h)
		3.5"/720 kB floppy services are supported (int 13h)
		8042 keyboard services are supported (int 9h)
		Serial services are supported (int 14h)
		CGA/mono video services are supported (int 10h)
		ACPI is supported
		USB legacy is supported
		BIOS boot specification is supported
		Function key-initiated network boot is supported
		Targeted content distribution is supported
	Platform Firmware Revision: 2.3

Handle 0x0100, DMI type 1, 27 bytes
System Information
	Manufacturer: Dell Inc.
	Product Name: PowerEdge R815
	Version: Not Specified
	Serial Number: 1WS0TS1
	UUID: 4c4c4544-0057-5310-8030-b1c04f545331
	Wake-up Type: Power Switch
	SKU Number: Not Specified
	Family: Not Specified

Handle 0x0200, DMI type 2, 9 bytes
Base Board Information
	Manufacturer: Dell Inc.
	Product Name: 0272WF
	Version: A00
	Serial Number: ..CN747511BU0163.
	Asset Tag: Not Specified

Handle 0x0300, DMI type 3, 21 bytes
Chassis Information
	Manufacturer: Dell Inc.
	Type: Rack Mount Chassis
	Lock: Present
	Version: Not Specified
	Serial Number: 1WS0TS1
	Asset Tag: Not Specified
	Boot-up State: Safe
	Power Supply State: Safe
	Thermal State: Safe
	Security Status: Unknown
	OEM Information: 0x00000000
	Height: 2 U
	Number Of Power Cords: Unspecified
	Contained Elements: 0

Handle 0x0400, DMI type 4, 40 bytes
Processor Information
	Socket Designation: CPU1
	Type: Central Processor
	Family: Opteron 6200
	Manufacturer: AMD
	ID: 12 0F 60 00 FF FB 8B 17
	Signature: Family 21, Model 1, Stepping 2
	Flags:
		FPU (Floating-point unit on-chip)
		VME (Virtual mode extension)
		DE (Debugging extension)
		PSE (Page size extension)
		TSC (Time stamp counter)
		MSR (Model specific registers)
		PAE (Physical address extension)
		MCE (Machine check exception)
		CX8 (CMPXCHG8 instruction supported)
		APIC (On-chip APIC hardware supported)
		SEP (Fast system call)
		MTRR (Memory type range registers)
		PGE (Page global enable)
		MCA (Machine check architecture)
		CMOV (Conditional move instruction supported)
		PAT (Page attribute table)
		PSE-36 (36-bit page size extension)
		CLFSH (CLFLUSH instruction supported)
		MMX (MMX technology supported)
		FXSR (FXSAVE and FXSTOR instructions supported)
		SSE (Streaming SIMD extensions)
		SSE2 (Streaming SIMD extensions 2)
		HTT (Multi-threading)
	Version: AMD Opteron(TM) Processor 6276                 
	Voltage: 1.1 V
	External Clock: 3200 MHz
	Max Speed: 3600 MHz
	Current Speed: 2300 MHz
	Status: Populated, Enabled
	Upgrade: Socket AM3
	L1 Cache Handle: 0x0700
	L2 Cache Handle: 0x0701
	L3 Cache Handle: 0x0702
	Serial Number: Not Specified
	Asset Tag: Not Specified
	Part Number: Not Specified
	Core Count: 16
	Core Enabled: 16
	Thread Count: 16
	Characteristics:
		64-bit capable

Handle 0x0401, DMI type 4, 40 bytes
Processor Information
	Socket Designation: CPU2
	Type: Central Processor
	Family: Opteron 6200
	Manufacturer: AMD
	ID: 12 0F 60 00 FF FB 8B 17
	Signature: Family 21, Model 1, Stepping 2
	Flags:
		FPU (Floating-point unit on-chip)
		VME (Virtual mode extension)
		DE (Debugging extension)
		PSE (Page size extension)
		TSC (Time stamp counter)
		MSR (Model specific registers)
		PAE (Physical address extension)
		MCE (Machine check exception)
		CX8 (CMPXCHG8 instruction supported)
		APIC (On-chip APIC hardware supported)
		SEP (Fast system call)
		MTRR (Memory type range registers)
		PGE (Page global enable)
		MCA (Machine check architecture)
		CMOV (Conditional move instruction supported)
		PAT (Page attribute table)
		PSE-36 (36-bit page size extension)
		CLFSH (CLFLUSH instruction supported)
		MMX (MMX technology supported)
		FXSR (FXSAVE and FXSTOR instructions supported)
		SSE (Streaming SIMD extensions)
		SSE2 (Streaming SIMD extensions 2)
		HTT (Multi-threading)
	Version: AMD Opteron(TM) Processor 6276                 
	Voltage: 1.1 V
	External Clock: 3200 MHz
	Max Speed: 3600 MHz
	Current Speed: 2300 MHz
	Status: Populated, Idle
	Upgrade: Socket AM3
	L1 Cache Handle: 0x0703
	L2 Cache Handle: 0x0704
	L3 Cache Handle: 0x0705
	Serial Number: Not Specified
	Asset Tag: Not Specified
	Part Number: Not Specified
	Core Count: 16
	Core Enabled: 16
	Thread Count: 16
	Characteristics:
		64-bit capable

Handle 0x0402, DMI type 4, 40 bytes
Processor Information
	Socket Designation: CPU3
	Type: Central Processor
	Family: Opteron 6200
	Manufacturer: AMD
	ID: 12 0F 60 00 FF FB 8B 17
	Signature: Family 21, Model 1, Stepping 2
	Flags:
		FPU (Floating-point unit on-chip)
		VME (Virtual mode extension)
		DE (Debugging extension)
		PSE (Page size extension)
		TSC (Time stamp counter)
		MSR (Model specific registers)
		PAE (Physical address extension)
		MCE (Machine check exception)
		CX8 (CMPXCHG8 instruction supported)
		APIC (On-chip APIC hardware supported)
		SEP (Fast system call)
		MTRR (Memory type range registers)
		PGE (Page global enable)
		MCA (Machine check architecture)
		CMOV (Conditional move instruction supported)
		PAT (Page attribute table)
		PSE-36 (36-bit page size extension)
		CLFSH (CLFLUSH instruction supported)
		MMX (MMX technology supported)
		FXSR (FXSAVE and FXSTOR instructions supported)
		SSE (Streaming SIMD extensions)
		SSE2 (Streaming SIMD extensions 2)
		HTT (Multi-threading)
	Version: AMD Opteron(TM) Processor 6276                 
	Voltage: 1.1 V
	External Clock: 3200 MHz
	Max Speed: 3600 MHz
	Current Speed: 2300 MHz
	Status: Populated, Idle
	Upgrade: Socket AM3
	L1 Cache Handle: 0x0706
	L2 Cache Handle: 0x0707
	L3 Cache Handle: 0x0708
	Serial Number: Not Specified
	Asset Tag: Not Specified
	Part Number: Not Specified
	Core Count: 16
	Core Enabled: 16
	Thread Count: 16
	Characteristics:
		64-bit capable

Handle 0x0403, DMI type 4, 40 bytes
Processor Information
	Socket Designation: CPU4
	Type: Central Processor
	Family: Opteron 6200
	Manufacturer: AMD
	ID: 12 0F 60 00 FF FB 8B 17
	Signature: Family 21, Model 1, Stepping 2
	Flags:
		FPU (Floating-point unit on-chip)
		VME (Virtual mode extension)
		DE (Debugging extension)
		PSE (Page size extension)
		TSC (Time stamp counter)
		MSR (Model specific registers)
		PAE (Physical address extension)
		MCE (Machine check exception)
		CX8 (CMPXCHG8 instruction supported)
		APIC (On-chip APIC hardware supported)
		SEP (Fast system call)
		MTRR (Memory type range registers)
		PGE (Page global enable)
		MCA (Machine check architecture)
		CMOV (Conditional move instruction supported)
		PAT (Page attribute table)
		PSE-36 (36-bit page size extension)
		CLFSH (CLFLUSH instruction supported)
		MMX (MMX technology supported)
		FXSR (FXSAVE and FXSTOR instructions supported)
		SSE (Streaming SIMD extensions)
		SSE2 (Streaming SIMD extensions 2)
		HTT (Multi-threading)
	Version: AMD Opteron(TM) Processor 6276                 
	Voltage: 1.1 V
	External Clock: 3200 MHz
	Max Speed: 3600 MHz
	Current Speed: 2300 MHz
	Status: Populated, Idle
	Upgrade: Socket AM3
	L1 Cache Handle: 0x0709
	L2 Cache Handle: 0x070A
	L3 Cache Handle: 0x070B
	Serial Number: Not Specified
	Asset Tag: Not Specified
	Part Number: Not Specified
	Core Count: 16
	Core Enabled: 16
	Thread Count: 16
	Characteristics:
		64-bit capable

Handle 0x0700, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 1
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 768 KiB
	Maximum Size: 768 KiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: 2-way Set-associative

Handle 0x0701, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 2
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 16 MiB
	Maximum Size: 16 MiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: 16-way Set-associative

Handle 0x0702, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 3
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 12 MiB
	Maximum Size: 12 MiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: Other

Handle 0x0703, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 1
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 768 KiB
	Maximum Size: 768 KiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: 2-way Set-associative

Handle 0x0704, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 2
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 16 MiB
	Maximum Size: 16 MiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: 16-way Set-associative

Handle 0x0705, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 3
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 12 MiB
	Maximum Size: 12 MiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: Other

Handle 0x0706, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 1
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 768 KiB
	Maximum Size: 768 KiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: 2-way Set-associative

Handle 0x0707, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 2
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 16 MiB
	Maximum Size: 16 MiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: 16-way Set-associative

Handle 0x0708, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 3
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 12 MiB
	Maximum Size: 12 MiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: Other

Handle 0x0709, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 1
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 768 KiB
	Maximum Size: 768 KiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: 2-way Set-associative

Handle 0x070A, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 2
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 16 MiB
	Maximum Size: 16 MiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: 16-way Set-associative

Handle 0x070B, DMI type 7, 19 bytes
Cache Information
	Socket Designation: Not Specified
	Configuration: Enabled, Not Socketed, Level 3
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 12 MiB
	Maximum Size: 12 MiB
	Supported SRAM Types:
		Unknown
	Installed SRAM Type: Unknown
	Speed: Unknown
	Error Correction Type: Multi-bit ECC
	System Type: Unified
	Associativity: Other

Handle 0x0800, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: DB-15 female
	Port Type: Video Port

Handle 0x0801, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: DB-15 female
	Port Type: Video Port

Handle 0x0802, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: Access Bus (USB)
	Port Type: USB

Handle 0x0803, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: Access Bus (USB)
	Port Type: USB

Handle 0x0804, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: Access Bus (USB)
	Port Type: USB

Handle 0x0805, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: Access Bus (USB)
	Port Type: USB

Handle 0x0806, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: Access Bus (USB)
	Port Type: USB

Handle 0x0807, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: Access Bus (USB)
	Port Type: USB

Handle 0x0808, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: INT_USB
	Internal Connector Type: Access Bus (USB)
	External Reference Designator: Not Specified
	External Connector Type: None
	Port Type: USB

Handle 0x0809, DMI type 126, 9 bytes
Inactive

Handle 0x080A, DMI type 126, 9 bytes
Inactive

Handle 0x080B, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: RJ-45
	Port Type: Network Port

Handle 0x080C, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: RJ-45
	Port Type: Network Port

Handle 0x080D, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: RJ-45
	Port Type: Network Port

Handle 0x080E, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: RJ-45
	Port Type: Network Port

Handle 0x080F, DMI type 8, 9 bytes
Port Connector Information
	Internal Reference Designator: Not Specified
	Internal Connector Type: None
	External Reference Designator: Not Specified
	External Connector Type: DB-9 male
	Port Type: Serial Port 16550A Compatible

Handle 0x0900, DMI type 9, 17 bytes
System Slot Information
	Designation: PCI1
	Type: PCI Express 2 x8
	Data Bus Width: 8x or x8
	Current Usage: Available
	Length: Long
	ID: 1
	Characteristics:
		3.3 V is provided
		PME signal is supported

Handle 0x0901, DMI type 9, 17 bytes
System Slot Information
	Designation: PCI2
	Type: PCI Express 2 x4
	Data Bus Width: 4x or x4
	Current Usage: Available
	Length: Short
	ID: 2
	Characteristics:
		3.3 V is provided
		PME signal is supported

Handle 0x0902, DMI type 9, 17 bytes
System Slot Information
	Designation: PCI3
	Type: PCI Express 2 x8
	Data Bus Width: 8x or x8
	Current Usage: Available
	Length: Short
	ID: 3
	Characteristics:
		3.3 V is provided
		PME signal is supported

Handle 0x0903, DMI type 9, 17 bytes
System Slot Information
	Designation: PCI4
	Type: PCI Express 2 x8
	Data Bus Width: 8x or x8
	Current Usage: Available
	Length: Short
	ID: 4
	Characteristics:
		3.3 V is provided
		PME signal is supported

Handle 0x0904, DMI type 9, 17 bytes
System Slot Information
	Designation: PCI5
	Type: PCI Express 2 x8
	Data Bus Width: 8x or x8
	Current Usage: Available
	Length: Long
	ID: 5
	Characteristics:
		3.3 V is provided
		PME signal is supported

Handle 0x0905, DMI type 9, 17 bytes
System Slot Information
	Designation: PCI6
	Type: PCI Express 2 x8
	Data Bus Width: 8x or x8
	Current Usage: Available
	Length: Long
	ID: 6
	Characteristics:
		3.3 V is provided
		PME signal is supported

Handle 0x0A00, DMI type 10, 16 bytes
On Board Device 1 Information
	Type: Video
	Status: Enabled
	Description: Embedded Matrox G200 Video
On Board Device 2 Information
	Type: Ethernet
	Status: Enabled
	Description: Embedded Broadcom 5709C NIC 1
On Board Device 3 Information
	Type: Ethernet
	Status: Enabled
	Description: Embedded Broadcom 5709C NIC 2
On Board Device 4 Information
	Type: Ethernet
	Status: Enabled
	Description: Embedded Broadcom 5709C NIC 3
On Board Device 5 Information
	Type: Ethernet
	Status: Enabled
	Description: Embedded Broadcom 5709C NIC 4
On Board Device 6 Information
	Type: SAS Controller
	Status: Enabled
	Description: Integrated PERC Controller

Handle 0x0B00, DMI type 11, 5 bytes
OEM Strings
	String 1: Dell System
	String 2: 5[0000]

Handle 0x7E00, DMI type 126, 170 bytes
Inactive

Handle 0x0C00, DMI type 12, 5 bytes
System Configuration Options
	Option 1: NVRAM_CLR:  Clear user settable NVRAM areas and set defaults
	Option 2: PWRD_EN:  Close to enable password

Handle 0x0D00, DMI type 13, 22 bytes
Firmware Language Information
	Language Description Format: Long
	Installable Languages: 1
		en|US|iso8859-1
	Currently Installed Language: en|US|iso8859-1

Handle 0x1000, DMI type 16, 15 bytes
Physical Memory Array
	Location: System Board Or Motherboard
	Use: System Memory
	Error Correction Type: Multi-bit ECC
	Maximum Capacity: 1 TiB
	Error Information Handle: Not Provided
	Number Of Devices: 32

Handle 0x1100, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 1
	Locator: DIMM_A1 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 27CC98E5
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1101, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 1
	Locator: DIMM_A2 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 273C989E
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1102, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 2
	Locator: DIMM_A3 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 1E4971B8
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1103, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 2
	Locator: DIMM_A4 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 27CC989D
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1104, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 3
	Locator: DIMM_A5 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 278C9908
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1105, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 3
	Locator: DIMM_A6 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 273C9889
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1106, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 4
	Locator: DIMM_A7 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 1E6971B0
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1107, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 4
	Locator: DIMM_A8 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 276C989F
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1108, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 5
	Locator: DIMM_B1 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 27CC98EB
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1109, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 5
	Locator: DIMM_B2 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 278C9905
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x110A, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 6
	Locator: DIMM_B3 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 278C98EA
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x110B, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 6
	Locator: DIMM_B4 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 278C98ED
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x110C, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 7
	Locator: DIMM_B5 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 271C98E6
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x110D, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 7
	Locator: DIMM_B6 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 278C9911
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x110E, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 8
	Locator: DIMM_B7 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 274C98E9
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x110F, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 8
	Locator: DIMM_B8 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 279C98EE
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1110, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 9
	Locator: DIMM_C1 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 273C98EC
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1111, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 9
	Locator: DIMM_C2 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 277C98E7
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1112, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 10
	Locator: DIMM_C3 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 276C9896
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1113, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 10
	Locator: DIMM_C4 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 27BC98A9
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1114, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 11
	Locator: DIMM_C5 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 273C98E9
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1115, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 11
	Locator: DIMM_C6 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 274C9898
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1116, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 12
	Locator: DIMM_C7 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 27BC98F4
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1117, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 12
	Locator: DIMM_C8 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 274C98EC
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1118, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 13
	Locator: DIMM_D1 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 27AC98E8
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1119, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 13
	Locator: DIMM_D2 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 277C9908
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x111A, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 14
	Locator: DIMM_D3 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 276C98ED
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x111B, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 14
	Locator: DIMM_D4 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 272C98EC
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x111C, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 15
	Locator: DIMM_D5 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 278C98E4
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x111D, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 15
	Locator: DIMM_D6 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 276C98E7
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x111E, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 16
	Locator: DIMM_D7 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 275C9920
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x111F, DMI type 17, 28 bytes
Memory Device
	Array Handle: 0x1000
	Error Information Handle: Not Provided
	Total Width: 72 bits
	Data Width: 64 bits
	Size: 2 GiB
	Form Factor: DIMM
	Set: 16
	Locator: DIMM_D8 
	Bank Locator: Not Specified
	Type: DDR3
	Type Detail: Synchronous Unbuffered (Unregistered)
	Speed: 1333 MT/s
	Manufacturer: 80AD000080AD
	Serial Number: 272C98EF
	Asset Tag: 01113700
	Part Number: HMT325U7BFR8A-H9  
	Rank: 1

Handle 0x1300, DMI type 19, 15 bytes
Memory Array Mapped Address
	Starting Address: 0x00000000000
	Ending Address: 0x0007FFFFFFF
	Range Size: 2 GiB
	Physical Array Handle: 0x1000
	Partition Width: 2

Handle 0x1301, DMI type 19, 15 bytes
Memory Array Mapped Address
	Starting Address: 0x00100000000
	Ending Address: 0x0107BFFFFFF
	Range Size: 63424 MiB
	Physical Array Handle: 0x1000
	Partition Width: 2

Handle 0x2000, DMI type 32, 11 bytes
System Boot Information
	Status: No errors detected

Handle 0x2600, DMI type 38, 18 bytes
IPMI Device Information
	Interface Type: KCS (Keyboard Control Style)
	Specification Version: 2.0
	I2C Slave Address: 0x10
	NV Storage Device: Not Present
	Base Address: 0x0000000000000CA8 (I/O)
	Register Spacing: 32-bit Boundaries

Handle 0x2900, DMI type 41, 11 bytes
Onboard Device
	Reference Designation: Embedded NIC 1                          
	Type: Ethernet
	Status: Enabled
	Type Instance: 1
	Bus Address: 0000:01:00.0

Handle 0x2901, DMI type 41, 11 bytes
Onboard Device
	Reference Designation: Embedded NIC 2                          
	Type: Ethernet
	Status: Enabled
	Type Instance: 2
	Bus Address: 0000:01:00.1

Handle 0x2902, DMI type 41, 11 bytes
Onboard Device
	Reference Designation: Embedded NIC 3                          
	Type: Ethernet
	Status: Enabled
	Type Instance: 3
	Bus Address: 0000:02:00.0

Handle 0x2903, DMI type 41, 11 bytes
Onboard Device
	Reference Designation: Embedded NIC 4                          
	Type: Ethernet
	Status: Enabled
	Type Instance: 4
	Bus Address: 0000:02:00.1

Handle 0x2904, DMI type 126, 11 bytes
Inactive

Handle 0x2905, DMI type 41, 11 bytes
Onboard Device
	Reference Designation: Integrated RAID                         
	Type: SAS Controller
	Status: Enabled
	Type Instance: 4
	Bus Address: 0000:05:00.0

Handle 0x2906, DMI type 41, 11 bytes
Onboard Device
	Reference Designation: Embedded Video                          
	Type: Video
	Status: Enabled
	Type Instance: 4
	Bus Address: 0000:0a:03.0

Handle 0xD000, DMI type 208, 16 bytes
OEM-specific Type
	Header and Data:
		D0 10 00 D0 02 00 FE 00 44 04 00 00 01 01 00 00

Handle 0xD200, DMI type 210, 12 bytes
OEM-specific Type
	Header and Data:
		D2 0C 00 D2 F8 03 04 03 06 80 04 05

Handle 0xD400, DMI type 212, 127 bytes
Dell Indexed I/O Access
	Index Port: 0x0070
	Data Port: 0x0071
	Type: Word Checksum
	Checked Range Start Index: 0x10
	Checked Range End Index: 0x2d
	Check Value Index: 0x2e
	Tokens:
		0x0042 (location 0x11, AND mask 0xfe, OR mask 0x01)
		0x0043 (location 0x11, AND mask 0xfe, OR mask 0x00)
		0x0000 (location 0x11, AND mask 0x9f, OR mask 0x20)
		0x0000 (location 0x11, AND mask 0x9f, OR mask 0x00)
		0x016e (location 0x11, AND mask 0x9f, OR mask 0x20)
		0x016d (location 0x11, AND mask 0x9f, OR mask 0x00)
		0x4031 (location 0x11, AND mask 0xfb, OR mask 0x00)
		0x4032 (location 0x11, AND mask 0xfb, OR mask 0x04)
		0x009d (location 0x11, AND mask 0xfd, OR mask 0x02)
		0x009e (location 0x11, AND mask 0xfd, OR mask 0x00)
		0x009f (location 0x26, AND mask 0xfe, OR mask 0x01)
		0x00a0 (location 0x26, AND mask 0xfe, OR mask 0x00)
		0x4028 (location 0x26, AND mask 0xdf, OR mask 0x20)
		0x4029 (location 0x26, AND mask 0xdf, OR mask 0x00)
		0x0238 (location 0x27, AND mask 0xbf, OR mask 0x40)
		0x0239 (location 0x27, AND mask 0xbf, OR mask 0x00)
		0x01f1 (location 0x27, AND mask 0xfc, OR mask 0x01)
		0x01f2 (location 0x27, AND mask 0xfc, OR mask 0x02)
		0x01f3 (location 0x27, AND mask 0xfc, OR mask 0x03)
		0x01f5 (location 0x27, AND mask 0xf3, OR mask 0x04)
		0x01f6 (location 0x27, AND mask 0xf3, OR mask 0x08)
		0x01f7 (location 0x27, AND mask 0xf3, OR mask 0x0c)

Handle 0xD401, DMI type 212, 252 bytes
Dell Indexed I/O Access
	Index Port: 0x0070
	Data Port: 0x0071
	Type: Negative Word Checksum
	Checked Range Start Index: 0x40
	Checked Range End Index: 0x5a
	Check Value Index: 0x6d
	Tokens:
		0x005c (location 0x78, AND mask 0xbf, OR mask 0x40)
		0x005d (location 0x78, AND mask 0xbf, OR mask 0x00)
		0x016c (location 0x57, AND mask 0xfc, OR mask 0x00)
		0x016b (location 0x57, AND mask 0xfc, OR mask 0x01)
		0x016a (location 0x57, AND mask 0xfc, OR mask 0x02)
		0x0212 (location 0x57, AND mask 0xef, OR mask 0x00)
		0x0211 (location 0x57, AND mask 0xef, OR mask 0x10)
		0x0000 (location 0x5b, AND mask 0xfb, OR mask 0x04)
		0x0000 (location 0x5b, AND mask 0xfb, OR mask 0x00)
		0x0177 (location 0x54, AND mask 0xfc, OR mask 0x00)
		0x0178 (location 0x54, AND mask 0xfc, OR mask 0x01)
		0x0179 (location 0x54, AND mask 0xfc, OR mask 0x02)
		0x017a (location 0x54, AND mask 0xfc, OR mask 0x03)
		0x4033 (location 0x54, AND mask 0xcf, OR mask 0x00)
		0x4034 (location 0x54, AND mask 0xcf, OR mask 0x10)
		0x4035 (location 0x54, AND mask 0xcf, OR mask 0x20)
		0x4036 (location 0x54, AND mask 0xcf, OR mask 0x30)
		0x401a (location 0x54, AND mask 0xfb, OR mask 0x04)
		0x401b (location 0x54, AND mask 0xfb, OR mask 0x00)
		0x401c (location 0x54, AND mask 0xf7, OR mask 0x08)
		0x401d (location 0x54, AND mask 0xf7, OR mask 0x00)
		0x4043 (location 0x58, AND mask 0xdf, OR mask 0x20)
		0x4042 (location 0x58, AND mask 0xdf, OR mask 0x00)
		0x4024 (location 0x58, AND mask 0xbf, OR mask 0x40)
		0x4025 (location 0x58, AND mask 0xbf, OR mask 0x00)
		0x006e (location 0x58, AND mask 0xfc, OR mask 0x01)
		0x002d (location 0x58, AND mask 0xfc, OR mask 0x02)
		0x01da (location 0x58, AND mask 0xfc, OR mask 0x03)
		0x4022 (location 0x58, AND mask 0xef, OR mask 0x10)
		0x4023 (location 0x58, AND mask 0xef, OR mask 0x00)
		0x00bb (location 0x58, AND mask 0xf3, OR mask 0x04)
		0x00bc (location 0x58, AND mask 0xf3, OR mask 0x08)
		0x01db (location 0x58, AND mask 0xf3, OR mask 0x0c)
		0x022d (location 0x55, AND mask 0xfe, OR mask 0x01)
		0x022e (location 0x55, AND mask 0xfe, OR mask 0x00)
		0x00d8 (location 0x55, AND mask 0x7f, OR mask 0x80)
		0x00d9 (location 0x55, AND mask 0x7f, OR mask 0x00)
		0x0254 (location 0x56, AND mask 0xdf, OR mask 0x00)
		0x0257 (location 0x56, AND mask 0xdf, OR mask 0x20)
		0x024d (location 0x56, AND mask 0xbf, OR mask 0x00)
		0x024e (location 0x56, AND mask 0xbf, OR mask 0x40)
		0x012d (location 0x56, AND mask 0x7f, OR mask 0x80)
		0x012e (location 0x56, AND mask 0x7f, OR mask 0x00)
		0xc000 (location 0x5c, AND mask 0x00, OR mask 0x0a)
		0xc003 (location 0x67, AND mask 0x00, OR mask 0x05)
		0x0083 (location 0x76, AND mask 0x00, OR mask 0x00)
		0x0084 (location 0x77, AND mask 0x00, OR mask 0x00)

Handle 0xD402, DMI type 212, 217 bytes
Dell Indexed I/O Access
	Index Port: 0x0072
	Data Port: 0x0073
	Type: Word Checksum
	Checked Range Start Index: 0xc0
	Checked Range End Index: 0xdd
	Check Value Index: 0xde
	Tokens:
		0x00d3 (location 0x80, AND mask 0x00, OR mask 0x02)
		0x00d4 (location 0x82, AND mask 0x00, OR mask 0x02)
		0x00d5 (location 0x84, AND mask 0x00, OR mask 0x02)
		0x00d6 (location 0x86, AND mask 0x00, OR mask 0x02)
		0x014a (location 0xc6, AND mask 0xbf, OR mask 0x40)
		0x014b (location 0xc6, AND mask 0xbf, OR mask 0x00)
		0x9000 (location 0xac, AND mask 0x00, OR mask 0x00)
		0x9001 (location 0xad, AND mask 0x00, OR mask 0x00)
		0x02c4 (location 0xc8, AND mask 0x7f, OR mask 0x00)
		0x02b3 (location 0xc8, AND mask 0x7f, OR mask 0x80)
		0x0000 (location 0xc9, AND mask 0xeb, OR mask 0x14)
		0x0000 (location 0xc9, AND mask 0xef, OR mask 0x10)
		0x00da (location 0xc9, AND mask 0xfb, OR mask 0x04)
		0x02d4 (location 0xc9, AND mask 0xfb, OR mask 0x00)
		0x02d5 (location 0xc9, AND mask 0xfb, OR mask 0x04)
		0x0000 (location 0xc9, AND mask 0xeb, OR mask 0x00)
		0x0000 (location 0xc9, AND mask 0x7f, OR mask 0x00)
		0x0000 (location 0xc9, AND mask 0x7f, OR mask 0x80)
		0x00ca (location 0xc9, AND mask 0xfc, OR mask 0x00)
		0x00cb (location 0xc9, AND mask 0xfc, OR mask 0x01)
		0x0000 (location 0xc9, AND mask 0xfc, OR mask 0x02)
		0x00de (location 0xe3, AND mask 0xfe, OR mask 0x01)
		0x4026 (location 0xc2, AND mask 0xfe, OR mask 0x01)
		0x4027 (location 0xc2, AND mask 0xfe, OR mask 0x00)
		0x02ff (location 0xc2, AND mask 0xf7, OR mask 0x08)
		0x0300 (location 0xc2, AND mask 0xf7, OR mask 0x00)
		0x0301 (location 0xc2, AND mask 0xef, OR mask 0x10)
		0x0302 (location 0xc2, AND mask 0xef, OR mask 0x00)
		0x0117 (location 0xca, AND mask 0xfe, OR mask 0x00)
		0x0118 (location 0xca, AND mask 0xfe, OR mask 0x01)
		0x0000 (location 0xca, AND mask 0xfd, OR mask 0x00)
		0x0000 (location 0xca, AND mask 0xfd, OR mask 0x02)
		0x0135 (location 0xcb, AND mask 0xfc, OR mask 0x00)
		0x0137 (location 0xcb, AND mask 0xfc, OR mask 0x01)
		0x4002 (location 0xc6, AND mask 0xdf, OR mask 0x00)
		0x4001 (location 0xc6, AND mask 0xdf, OR mask 0x20)
		0x01fc (location 0xc5, AND mask 0xbf, OR mask 0x00)
		0x01fd (location 0xc5, AND mask 0xbf, OR mask 0x40)
		0x0000 (location 0xc5, AND mask 0x7f, OR mask 0x80)
		0x0000 (location 0xc5, AND mask 0x7f, OR mask 0x00)

Handle 0xD403, DMI type 212, 177 bytes
Dell Indexed I/O Access
	Index Port: 0x0072
	Data Port: 0x0073
	Type: Word Checksum
	Checked Range Start Index: 0xc0
	Checked Range End Index: 0xdd
	Check Value Index: 0xde
	Tokens:
		0x0232 (location 0xc0, AND mask 0x07, OR mask 0x10)
		0x0231 (location 0xc0, AND mask 0x07, OR mask 0x20)
		0x026f (location 0xc0, AND mask 0x07, OR mask 0x30)
		0x0270 (location 0xc0, AND mask 0x07, OR mask 0x40)
		0x0271 (location 0xc0, AND mask 0x07, OR mask 0x50)
		0x0272 (location 0xc0, AND mask 0x07, OR mask 0x60)
		0x0321 (location 0xc0, AND mask 0x07, OR mask 0x70)
		0x0322 (location 0xc0, AND mask 0x07, OR mask 0x00)
		0x026e (location 0xc0, AND mask 0x07, OR mask 0x00)
		0x02a1 (location 0xc5, AND mask 0xfb, OR mask 0x00)
		0x02a2 (location 0xc5, AND mask 0xfb, OR mask 0x04)
		0x0000 (location 0xc6, AND mask 0xfe, OR mask 0x00)
		0x0000 (location 0xc6, AND mask 0xfe, OR mask 0x01)
		0x0140 (location 0xc7, AND mask 0xef, OR mask 0x10)
		0x0141 (location 0xc7, AND mask 0xef, OR mask 0x00)
		0x02fb (location 0xc7, AND mask 0xfd, OR mask 0x00)
		0x02fc (location 0xc7, AND mask 0xfd, OR mask 0x02)
		0x01c4 (location 0xd0, AND mask 0xfe, OR mask 0x00)
		0x01c5 (location 0xd0, AND mask 0xfe, OR mask 0x01)
		0x0173 (location 0xd0, AND mask 0xbf, OR mask 0x40)
		0x0174 (location 0xd0, AND mask 0xbf, OR mask 0x00)
		0x02ab (location 0xd0, AND mask 0xdf, OR mask 0x20)
		0x02ac (location 0xd0, AND mask 0xdf, OR mask 0x00)
		0x02a9 (location 0xd0, AND mask 0xef, OR mask 0x10)
		0x02aa (location 0xd0, AND mask 0xef, OR mask 0x00)
		0x026a (location 0xdb, AND mask 0xfe, OR mask 0x00)
		0x026b (location 0xdb, AND mask 0xfe, OR mask 0x01)
		0x027b (location 0xdb, AND mask 0xfd, OR mask 0x00)
		0x027c (location 0xdb, AND mask 0xfd, OR mask 0x02)
		0x02b6 (location 0xdc, AND mask 0x3f, OR mask 0x40)
		0x0000 (location 0xdc, AND mask 0x3f, OR mask 0x80)
		0x02b8 (location 0xdc, AND mask 0x3f, OR mask 0x00)

Handle 0xD800, DMI type 216, 9 bytes
OEM-specific Type
	Header and Data:
		D8 09 00 D8 01 02 01 00 00
	Strings:
		MATROX
		VGA/VBE BIOS, Version V3.8WO

Handle 0xDE00, DMI type 222, 16 bytes
OEM-specific Type
	Header and Data:
		DE 10 00 DE 01 08 FF FF 00 00 00 00 00 02 00 01

Handle 0xE000, DMI type 224, 11 bytes
OEM-specific Type
	Header and Data:
		E0 0B 00 E0 01 00 07 FF FF 01 02
	Strings:
		FFFFFF
		FFFFFF

Handle 0xE100, DMI type 225, 149 bytes
OEM-specific Type
	Header and Data:
		E1 95 00 E1 01 01 00 04 00 02 01 04 00 03 02 04
		00 04 03 04 00 05 00 11 00 06 01 11 00 07 02 11
		00 08 03 11 00 09 04 11 00 0A 05 11 00 0B 06 11
		00 0C 07 11 00 0D 08 11 00 0E 09 11 00 0F 0A 11
		00 10 0B 11 00 11 0C 11 00 12 0D 11 00 13 0E 11
		00 14 0F 11 00 15 10 11 00 16 11 11 00 17 12 11
		00 18 13 11 00 19 14 11 00 1A 15 11 00 1B 16 11
		00 1C 17 11 00 1D 18 11 00 1E 19 11 00 1F 1A 11
		00 20 1B 11 00 21 1C 11 00 22 1D 11 00 23 1E 11
		00 24 1F 11 00
	Strings:
		CPU.Socket.1
		CPU.Socket.2
		CPU.Socket.3
		CPU.Socket.4
		DIMM.Socket.A1
		DIMM.Socket.A2
		DIMM.Socket.A3
		DIMM.Socket.A4
		DIMM.Socket.A5
		DIMM.Socket.A6
		DIMM.Socket.A7
		DIMM.Socket.A8
		DIMM.Socket.B1
		DIMM.Socket.B2
		DIMM.Socket.B3
		DIMM.Socket.B4
		DIMM.Socket.B5
		DIMM.Socket.B6
		DIMM.Socket.B7
		DIMM.Socket.B8
		DIMM.Socket.C1
		DIMM.Socket.C2
		DIMM.Socket.C3
		DIMM.Socket.C4
		DIMM.Socket.C5
		DIMM.Socket.C6
		DIMM.Socket.C7
		DIMM.Socket.C8
		DIMM.Socket.D1
		DIMM.Socket.D2
		DIMM.Socket.D3
		DIMM.Socket.D4
		DIMM.Socket.D5
		DIMM.Socket.D6
		DIMM.Socket.D7
		DIMM.Socket.D8

Handle 0x7F00, DMI type 127, 4 bytes
End Of Table

FRU Device Description : Builtin FRU Device (ID 0)
 Board Mfg Date        : Unspecified
 Board Mfg             : DELL
 Board Product         : PowerEdge R815                
 Board Serial          : CN747511BU0163
 Board Part Number     : 0272WFA00
 Product Manufacturer  : DELL
 Product Version       : 02
 Product Serial        : 1WS0TS1

FRU Device Description : PS 1 (ID 2)
 Board Mfg Date        : Unspecified
 Board Mfg             : DELL
 Board Product         : PWR SPLY,1100W,RDNT           
 Board Serial          : CN716151920DA0
 Board Part Number     : 0TCVRRA01

FRU Device Description : PS 2 (ID 3)
 Board Mfg Date        : Unspecified
 Board Mfg             : DELL
 Board Product         : PWR SPLY,1100W,RDNT           
 Board Serial          : CN716151920DA1
 Board Part Number     : 0TCVRRA01

FRU Device Description : Storage (ID 1)
 Board Mfg Date        : Unspecified
 Board Mfg             : DELL
 Board Product         : FRU256,DELL P/N 03K345A00     
 Board Serial          : CN137401C203J3
 Board Part Number     : 0XXFVXA05

FRU Device Description : Back Plane (ID 4)
 Board Mfg Date        : Unspecified
 Board Mfg             : DELL
 Board Product         : FRU256,DELL P/N 03K345A00     
 Board Serial          : CN645351AIN3X0
 Board Part Number     : 0WR7PPA00

FRU Device Description : CPU Planar (ID 5)
 Board Mfg Date        : Unspecified
 Board Mfg             : DELL
 Board Product         : PowerEdge R815                
 Board Serial          : CN747511AT0046
 Board Part Number     : 0FP13TA02

NAME                        SIZE MODEL            ROTA TYPE
sda                       272.3G PERC H700           1 disk
└─sda1                    272.2G                     1 part
sdb                       558.4G PERC H700           1 disk
├─sdb1                        1G                     1 part
├─sdb2                        2G                     1 part
└─sdb3                    555.3G                     1 part
  └─ubuntu--vg-ubuntu--lv   100G                     1 lvm
sdc                       558.4G PERC H700           1 disk
└─sdc1                    558.4G                     1 part
sdd                         200G VIRTUAL-DISK        1 disk
sde                           5G VIRTUAL-DISK        1 disk
sdf                         100G VIRTUAL-DISK        1 disk
sdg                           5G VIRTUAL-DISK        1 disk
sdh                           8G VIRTUAL-DISK        1 disk
sdi                           8G VIRTUAL-DISK        1 disk
sdj                          10G VIRTUAL-DISK        1 disk
sdk                           8G VIRTUAL-DISK        1 disk
sdl                           8G VIRTUAL-DISK        1 disk
sdm                          50G VIRTUAL-DISK        1 disk
sdn                           8G VIRTUAL-DISK        1 disk
sr0                        1024M DVD+-RW DS-8A5SH    1 rom
Architecture:                            x86_64
CPU op-mode(s):                          32-bit, 64-bit
Address sizes:                           48 bits physical, 48 bits virtual
Byte Order:                              Little Endian
CPU(s):                                  64
On-line CPU(s) list:                     0-63
Vendor ID:                               AuthenticAMD
Model name:                              AMD Opteron(TM) Processor 6276
CPU family:                              21
Model:                                   1
Thread(s) per core:                      2
Core(s) per socket:                      8
Socket(s):                               4
Stepping:                                2
Microcode version:                       0x600063e
BogoMIPS:                                4600.37
Flags:                                   fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush mmx fxsr sse sse2 ht syscall nx mmxext fxsr_opt pdpe1gb rdtscp lm constant_tsc rep_good nopl nonstop_tsc cpuid extd_apicid amd_dcm aperfmperf pni pclmulqdq monitor ssse3 cx16 sse4_1 sse4_2 popcnt aes xsave avx lahf_lm cmp_legacy svm extapic cr8_legacy abm sse4a misalignsse 3dnowprefetch osvw ibs xop skinit wdt fma4 nodeid_msr topoext perfctr_core perfctr_nb cpb hw_pstate ssbd ibpb vmmcall arat npt lbrv svm_lock nrip_save tsc_scale vmcb_clean flushbyasid decodeassists pausefilter pfthreshold
Virtualization:                          AMD-V
L1d cache:                               1 MiB (64 instances)
L1i cache:                               2 MiB (32 instances)
L2 cache:                                64 MiB (32 instances)
L3 cache:                                48 MiB (8 instances)
NUMA node(s):                            8
NUMA node0 CPU(s):                       0-28:4
NUMA node1 CPU(s):                       32-60:4
NUMA node2 CPU(s):                       2-30:4
NUMA node3 CPU(s):                       34-62:4
NUMA node4 CPU(s):                       3-31:4
NUMA node5 CPU(s):                       35-63:4
NUMA node6 CPU(s):                       1-29:4
NUMA node7 CPU(s):                       33-61:4
Vulnerability Gather data sampling:      Not affected
Vulnerability Indirect target selection: Not affected
Vulnerability Itlb multihit:             Not affected
Vulnerability L1tf:                      Not affected
Vulnerability Mds:                       Not affected
Vulnerability Meltdown:                  Not affected
Vulnerability Mmio stale data:           Not affected
Vulnerability Reg file data sampling:    Not affected
Vulnerability Retbleed:                  Mitigation; untrained return thunk; SMT vulnerable
Vulnerability Spec rstack overflow:      Not affected
Vulnerability Spec store bypass:         Mitigation; Speculative Store Bypass disabled via prctl
Vulnerability Spectre v1:                Mitigation; usercopy/swapgs barriers and __user pointer sanitization
Vulnerability Spectre v2:                Mitigation; Retpolines; IBPB conditional; STIBP disabled; RSB filling; PBRSB-eIBRS Not affected; BHI Not affected
Vulnerability Srbds:                     Not affected
Vulnerability Tsa:                       Not affected
Vulnerability Tsx async abort:           Not affected
Vulnerability Vmscape:                   Not affected
00:00.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD/ATI] RD890S/SR5650 Host Bridge [1002:5a13] (rev 02)
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, NUMA node 0
	Capabilities: [f0] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [c4] HyperTransport: Slave or Primary Interface
	Capabilities: [40] HyperTransport: Retry Mode
	Capabilities: [54] HyperTransport: UnitID Clumping
	Capabilities: [9c] HyperTransport: #1a

00:02.0 PCI bridge [0604]: Advanced Micro Devices, Inc. [AMD/ATI] RD890/RD9x0/RX980 PCI to PCI bridge (PCI Express GFX port 0) [1002:5a16] (prog-if 00 [Normal decode])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, IRQ 25, NUMA node 0
	Bus: primary=00, secondary=01, subordinate=01, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: e6000000-e9ffffff [size=64M] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [50] Power Management version 3
	Capabilities: [58] Express Root Port (Slot+), IntMsgNum 0
	Capabilities: [a0] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [b0] Subsystem: Dell Device [1028:0444]
	Capabilities: [b8] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [100] Vendor Specific Information: ID=0001 Rev=1 Len=010 <?>
	Capabilities: [150] Advanced Error Reporting
	Capabilities: [190] Access Control Services
	Kernel driver in use: pcieport

00:03.0 PCI bridge [0604]: Advanced Micro Devices, Inc. [AMD/ATI] RD890/RD9x0 PCI to PCI bridge (PCI Express GFX port 1) [1002:5a17] (prog-if 00 [Normal decode])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, IRQ 26, NUMA node 0
	Bus: primary=00, secondary=02, subordinate=02, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: ea000000-edffffff [size=64M] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [50] Power Management version 3
	Capabilities: [58] Express Root Port (Slot+), IntMsgNum 0
	Capabilities: [a0] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [b0] Subsystem: Dell Device [1028:0444]
	Capabilities: [b8] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [100] Vendor Specific Information: ID=0001 Rev=1 Len=010 <?>
	Capabilities: [150] Advanced Error Reporting
	Capabilities: [190] Access Control Services
	Kernel driver in use: pcieport

00:04.0 PCI bridge [0604]: Advanced Micro Devices, Inc. [AMD/ATI] RD890/RD9x0/RX980 PCI to PCI bridge (PCI Express GPP Port 0) [1002:5a18] (prog-if 00 [Normal decode])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, IRQ 27, NUMA node 0
	Bus: primary=00, secondary=03, subordinate=08, sec-latency=0
	I/O behind bridge: f000-ffff [size=4K] [16-bit]
	Memory behind bridge: ef000000-ef1fffff [size=2M] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [50] Power Management version 3
	Capabilities: [58] Express Root Port (Slot+), IntMsgNum 0
	Capabilities: [a0] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [b0] Subsystem: Dell Device [1028:0444]
	Capabilities: [b8] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [100] Vendor Specific Information: ID=0001 Rev=1 Len=010 <?>
	Capabilities: [150] Advanced Error Reporting
	Capabilities: [190] Access Control Services
	Kernel driver in use: pcieport

00:09.0 PCI bridge [0604]: Advanced Micro Devices, Inc. [AMD/ATI] RD890/RD9x0/RX980 PCI to PCI bridge (PCI Express GPP Port 4) [1002:5a1c] (prog-if 00 [Normal decode])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, IRQ 29, NUMA node 0
	Bus: primary=00, secondary=09, subordinate=09, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: [disabled] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [50] Power Management version 3
	Capabilities: [58] Express Root Port (Slot+), IntMsgNum 0
	Capabilities: [a0] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [b0] Subsystem: Dell Device [1028:0444]
	Capabilities: [b8] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [100] Vendor Specific Information: ID=0001 Rev=1 Len=010 <?>
	Capabilities: [150] Advanced Error Reporting
	Capabilities: [190] Access Control Services
	Kernel driver in use: pcieport

00:11.0 SATA controller [0106]: Advanced Micro Devices, Inc. [AMD/ATI] SB7x0/SB8x0/SB9x0 SATA Controller [IDE mode] [1002:4390] (prog-if 01 [AHCI 1.0])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, 66MHz, medium devsel, latency 64, IRQ 22, NUMA node 0
	I/O ports at ece8 [size=8]
	I/O ports at ecf8 [size=4]
	I/O ports at ecf0 [size=8]
	I/O ports at ecfc [size=4]
	I/O ports at ecd0 [size=16]
	Memory at ef2ff800 (32-bit, non-prefetchable) [size=1K]
	Capabilities: [60] Power Management version 2
	Capabilities: [70] SATA HBA v1.0
	Kernel driver in use: ahci

00:12.0 USB controller [0c03]: Advanced Micro Devices, Inc. [AMD/ATI] SB7x0/SB8x0/SB9x0 USB OHCI0 Controller [1002:4397] (prog-if 10 [OHCI])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, 66MHz, medium devsel, latency 64, IRQ 16, NUMA node 0
	Memory at ef2fb000 (32-bit, non-prefetchable) [size=4K]
	Kernel driver in use: ohci-pci

00:12.1 USB controller [0c03]: Advanced Micro Devices, Inc. [AMD/ATI] SB7x0 USB OHCI1 Controller [1002:4398] (prog-if 10 [OHCI])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, 66MHz, medium devsel, latency 64, IRQ 16, NUMA node 0
	Memory at ef2fc000 (32-bit, non-prefetchable) [size=4K]
	Kernel driver in use: ohci-pci

00:12.2 USB controller [0c03]: Advanced Micro Devices, Inc. [AMD/ATI] SB7x0/SB8x0/SB9x0 USB EHCI Controller [1002:4396] (prog-if 20 [EHCI])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, 66MHz, medium devsel, latency 64, IRQ 17, NUMA node 0
	Memory at ef2ffe00 (32-bit, non-prefetchable) [size=256]
	Capabilities: [c0] Power Management version 2
	Capabilities: [e4] Debug port: BAR=1 offset=00e0
	Kernel driver in use: ehci-pci

00:13.0 USB controller [0c03]: Advanced Micro Devices, Inc. [AMD/ATI] SB7x0/SB8x0/SB9x0 USB OHCI0 Controller [1002:4397] (prog-if 10 [OHCI])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, 66MHz, medium devsel, latency 64, IRQ 18, NUMA node 0
	Memory at ef2fd000 (32-bit, non-prefetchable) [size=4K]
	Kernel driver in use: ohci-pci

00:13.1 USB controller [0c03]: Advanced Micro Devices, Inc. [AMD/ATI] SB7x0 USB OHCI1 Controller [1002:4398] (prog-if 10 [OHCI])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, 66MHz, medium devsel, latency 64, IRQ 18, NUMA node 0
	Memory at ef2fe000 (32-bit, non-prefetchable) [size=4K]
	Kernel driver in use: ohci-pci

00:13.2 USB controller [0c03]: Advanced Micro Devices, Inc. [AMD/ATI] SB7x0/SB8x0/SB9x0 USB EHCI Controller [1002:4396] (prog-if 20 [EHCI])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, 66MHz, medium devsel, latency 64, IRQ 19, NUMA node 0
	Memory at ef2fff00 (32-bit, non-prefetchable) [size=256]
	Capabilities: [c0] Power Management version 2
	Capabilities: [e4] Debug port: BAR=1 offset=00e0
	Kernel driver in use: ehci-pci

00:14.0 SMBus [0c05]: Advanced Micro Devices, Inc. [AMD/ATI] SBx00 SMBus Controller [1002:4385] (rev 3d)
	Subsystem: Dell Device [1028:0444]
	Flags: 66MHz, medium devsel, NUMA node 0
	Capabilities: [b0] HyperTransport: MSI Mapping Enable- Fixed+
	Kernel driver in use: piix4_smbus

00:14.3 ISA bridge [0601]: Advanced Micro Devices, Inc. [AMD/ATI] SB7x0/SB8x0/SB9x0 LPC host controller [1002:439d]
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, 66MHz, medium devsel, latency 0, NUMA node 0

00:14.4 PCI bridge [0604]: Advanced Micro Devices, Inc. [AMD/ATI] SBx00 PCI to PCI Bridge [1002:4384] (prog-if 01 [Subtractive decode])
	Flags: bus master, 66MHz, medium devsel, latency 64, NUMA node 0
	Bus: primary=00, secondary=0a, subordinate=0a, sec-latency=64
	I/O behind bridge: [disabled] [16-bit]
	Memory behind bridge: ee000000-eeffffff [size=16M] [32-bit]
	Prefetchable memory behind bridge: e5800000-e5ffffff [size=8M] [32-bit]

00:18.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 0 [1022:1600]
	Flags: fast devsel, NUMA node 0
	Capabilities: [80] HyperTransport: Host or Secondary Interface
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [c0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface

00:18.1 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 1 [1022:1601]
	Flags: fast devsel, NUMA node 0

00:18.2 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 2 [1022:1602]
	Flags: fast devsel, NUMA node 0

00:18.3 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 3 [1022:1603]
	Flags: fast devsel, NUMA node 0
	Capabilities: [f0] Secure device <?>
	Kernel driver in use: k10temp

00:18.4 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 4 [1022:1604]
	Flags: fast devsel, NUMA node 0
	Capabilities: [e0] HyperTransport: Host or Secondary Interface
	Kernel driver in use: fam15h_power

00:18.5 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 5 [1022:1605]
	Flags: fast devsel, NUMA node 0

00:19.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 0 [1022:1600]
	Flags: fast devsel, NUMA node 1
	Capabilities: [80] HyperTransport: Host or Secondary Interface
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface

00:19.1 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 1 [1022:1601]
	Flags: fast devsel, NUMA node 1

00:19.2 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 2 [1022:1602]
	Flags: fast devsel, NUMA node 1

00:19.3 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 3 [1022:1603]
	Flags: fast devsel, NUMA node 1
	Capabilities: [f0] Secure device <?>
	Kernel driver in use: k10temp

00:19.4 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 4 [1022:1604]
	Flags: fast devsel, NUMA node 1
	Capabilities: [80] HyperTransport: Host or Secondary Interface

00:19.5 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 5 [1022:1605]
	Flags: fast devsel, NUMA node 1

00:1a.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 0 [1022:1600]
	Flags: fast devsel, NUMA node 2
	Capabilities: [80] HyperTransport: Host or Secondary Interface
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [c0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface

00:1a.1 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 1 [1022:1601]
	Flags: fast devsel, NUMA node 2

00:1a.2 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 2 [1022:1602]
	Flags: fast devsel, NUMA node 2

00:1a.3 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 3 [1022:1603]
	Flags: fast devsel, NUMA node 2
	Capabilities: [f0] Secure device <?>
	Kernel driver in use: k10temp

00:1a.4 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 4 [1022:1604]
	Flags: fast devsel, NUMA node 2
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface
	Kernel driver in use: fam15h_power

00:1a.5 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 5 [1022:1605]
	Flags: fast devsel, NUMA node 2

00:1b.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 0 [1022:1600]
	Flags: fast devsel, NUMA node 3
	Capabilities: [80] HyperTransport: Host or Secondary Interface
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface

00:1b.1 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 1 [1022:1601]
	Flags: fast devsel, NUMA node 3

00:1b.2 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 2 [1022:1602]
	Flags: fast devsel, NUMA node 3

00:1b.3 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 3 [1022:1603]
	Flags: fast devsel, NUMA node 3
	Capabilities: [f0] Secure device <?>
	Kernel driver in use: k10temp

00:1b.4 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 4 [1022:1604]
	Flags: fast devsel, NUMA node 3
	Capabilities: [80] HyperTransport: Host or Secondary Interface

00:1b.5 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 5 [1022:1605]
	Flags: fast devsel, NUMA node 3

00:1c.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 0 [1022:1600]
	Flags: fast devsel, NUMA node 4
	Capabilities: [80] HyperTransport: Host or Secondary Interface
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [c0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface

00:1c.1 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 1 [1022:1601]
	Flags: fast devsel, NUMA node 4

00:1c.2 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 2 [1022:1602]
	Flags: fast devsel, NUMA node 4

00:1c.3 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 3 [1022:1603]
	Flags: fast devsel, NUMA node 4
	Capabilities: [f0] Secure device <?>
	Kernel driver in use: k10temp

00:1c.4 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 4 [1022:1604]
	Flags: fast devsel, NUMA node 4
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface
	Kernel driver in use: fam15h_power

00:1c.5 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 5 [1022:1605]
	Flags: fast devsel, NUMA node 4

00:1d.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 0 [1022:1600]
	Flags: fast devsel, NUMA node 5
	Capabilities: [80] HyperTransport: Host or Secondary Interface
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface

00:1d.1 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 1 [1022:1601]
	Flags: fast devsel, NUMA node 5

00:1d.2 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 2 [1022:1602]
	Flags: fast devsel, NUMA node 5

00:1d.3 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 3 [1022:1603]
	Flags: fast devsel, NUMA node 5
	Capabilities: [f0] Secure device <?>
	Kernel driver in use: k10temp

00:1d.4 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 4 [1022:1604]
	Flags: fast devsel, NUMA node 5
	Capabilities: [80] HyperTransport: Host or Secondary Interface

00:1d.5 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 5 [1022:1605]
	Flags: fast devsel, NUMA node 5

00:1e.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 0 [1022:1600]
	Flags: fast devsel, NUMA node 6
	Capabilities: [80] HyperTransport: Host or Secondary Interface
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [c0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface

00:1e.1 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 1 [1022:1601]
	Flags: fast devsel, NUMA node 6

00:1e.2 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 2 [1022:1602]
	Flags: fast devsel, NUMA node 6

00:1e.3 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 3 [1022:1603]
	Flags: fast devsel, NUMA node 6
	Capabilities: [f0] Secure device <?>
	Kernel driver in use: k10temp

00:1e.4 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 4 [1022:1604]
	Flags: fast devsel, NUMA node 6
	Capabilities: [e0] HyperTransport: Host or Secondary Interface
	Kernel driver in use: fam15h_power

00:1e.5 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 5 [1022:1605]
	Flags: fast devsel, NUMA node 6

00:1f.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 0 [1022:1600]
	Flags: fast devsel, NUMA node 7
	Capabilities: [80] HyperTransport: Host or Secondary Interface
	Capabilities: [a0] HyperTransport: Host or Secondary Interface
	Capabilities: [e0] HyperTransport: Host or Secondary Interface

00:1f.1 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 1 [1022:1601]
	Flags: fast devsel, NUMA node 7

00:1f.2 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 2 [1022:1602]
	Flags: fast devsel, NUMA node 7

00:1f.3 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 3 [1022:1603]
	Flags: fast devsel, NUMA node 7
	Capabilities: [f0] Secure device <?>
	Kernel driver in use: k10temp

00:1f.4 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 4 [1022:1604]
	Flags: fast devsel, NUMA node 7
	Capabilities: [80] HyperTransport: Host or Secondary Interface

00:1f.5 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD] Family 15h Processor Function 5 [1022:1605]
	Flags: fast devsel, NUMA node 7

01:00.0 Ethernet controller [0200]: Broadcom Inc. and subsidiaries NetXtreme II BCM5709 Gigabit Ethernet [14e4:1639] (rev 20)
	DeviceName: Embedded NIC 1                          
	Subsystem: Dell Device [1028:1f26]
	Flags: bus master, fast devsel, latency 0, IRQ 41, NUMA node 0
	Memory at e6000000 (64-bit, non-prefetchable) [size=32M]
	Capabilities: [48] Power Management version 3
	Capabilities: [50] Vital Product Data
	Capabilities: [58] MSI: Enable- Count=1/16 Maskable- 64bit+
	Capabilities: [a0] MSI-X: Enable+ Count=9 Masked-
	Capabilities: [ac] Express Endpoint, IntMsgNum 0
	Capabilities: [100] Device Serial Number d0-67-e5-ff-fe-fa-8a-5c
	Capabilities: [110] Advanced Error Reporting
	Capabilities: [150] Power Budgeting <?>
	Capabilities: [160] Virtual Channel
	Kernel driver in use: bnx2

01:00.1 Ethernet controller [0200]: Broadcom Inc. and subsidiaries NetXtreme II BCM5709 Gigabit Ethernet [14e4:1639] (rev 20)
	DeviceName: Embedded NIC 2                          
	Subsystem: Dell Device [1028:1f26]
	Flags: bus master, fast devsel, latency 0, IRQ 42, NUMA node 0
	Memory at e8000000 (64-bit, non-prefetchable) [size=32M]
	Capabilities: [48] Power Management version 3
	Capabilities: [50] Vital Product Data
	Capabilities: [58] MSI: Enable- Count=1/16 Maskable- 64bit+
	Capabilities: [a0] MSI-X: Enable- Count=9 Masked-
	Capabilities: [ac] Express Endpoint, IntMsgNum 0
	Capabilities: [100] Device Serial Number d0-67-e5-ff-fe-fa-8a-5e
	Capabilities: [110] Advanced Error Reporting
	Capabilities: [150] Power Budgeting <?>
	Capabilities: [160] Virtual Channel
	Kernel driver in use: bnx2

02:00.0 Ethernet controller [0200]: Broadcom Inc. and subsidiaries NetXtreme II BCM5709 Gigabit Ethernet [14e4:1639] (rev 20)
	DeviceName: Embedded NIC 3                          
	Subsystem: Dell Device [1028:1f26]
	Flags: bus master, fast devsel, latency 0, IRQ 43, NUMA node 0
	Memory at ea000000 (64-bit, non-prefetchable) [size=32M]
	Capabilities: [48] Power Management version 3
	Capabilities: [50] Vital Product Data
	Capabilities: [58] MSI: Enable- Count=1/16 Maskable- 64bit+
	Capabilities: [a0] MSI-X: Enable- Count=9 Masked-
	Capabilities: [ac] Express Endpoint, IntMsgNum 0
	Capabilities: [100] Device Serial Number d0-67-e5-ff-fe-fa-8a-60
	Capabilities: [110] Advanced Error Reporting
	Capabilities: [150] Power Budgeting <?>
	Capabilities: [160] Virtual Channel
	Kernel driver in use: bnx2

02:00.1 Ethernet controller [0200]: Broadcom Inc. and subsidiaries NetXtreme II BCM5709 Gigabit Ethernet [14e4:1639] (rev 20)
	DeviceName: Embedded NIC 4                          
	Subsystem: Dell Device [1028:1f26]
	Flags: bus master, fast devsel, latency 0, IRQ 45, NUMA node 0
	Memory at ec000000 (64-bit, non-prefetchable) [size=32M]
	Capabilities: [48] Power Management version 3
	Capabilities: [50] Vital Product Data
	Capabilities: [58] MSI: Enable- Count=1/16 Maskable- 64bit+
	Capabilities: [a0] MSI-X: Enable- Count=9 Masked-
	Capabilities: [ac] Express Endpoint, IntMsgNum 0
	Capabilities: [100] Device Serial Number d0-67-e5-ff-fe-fa-8a-62
	Capabilities: [110] Advanced Error Reporting
	Capabilities: [150] Power Budgeting <?>
	Capabilities: [160] Virtual Channel
	Kernel driver in use: bnx2

03:00.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624] (rev bb) (prog-if 00 [Normal decode])
	Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Flags: bus master, fast devsel, latency 0, IRQ 30, NUMA node 0
	Memory at ef1e0000 (32-bit, non-prefetchable) [size=128K]
	Bus: primary=03, secondary=04, subordinate=08, sec-latency=0
	I/O behind bridge: f000-ffff [size=4K] [16-bit]
	Memory behind bridge: ef000000-ef0fffff [size=1M] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [40] Power Management version 3
	Capabilities: [48] MSI: Enable- Count=1/4 Maskable+ 64bit+
	Capabilities: [68] Express Upstream Port, IntMsgNum 0
	Capabilities: [a4] Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Capabilities: [100] Vendor Specific Information: ID=ffff Rev=15 Len=008 <?>
	Capabilities: [fb4] Advanced Error Reporting
	Capabilities: [138] Power Budgeting <?>
	Capabilities: [148] Virtual Channel
	Capabilities: [950] Vendor Specific Information: ID=0001 Rev=0 Len=010 <?>
	Kernel driver in use: pcieport

04:00.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624] (rev bb) (prog-if 00 [Normal decode])
	Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Flags: bus master, fast devsel, latency 0, IRQ 31, NUMA node 0
	Bus: primary=04, secondary=05, subordinate=05, sec-latency=0
	I/O behind bridge: f000-ffff [size=4K] [16-bit]
	Memory behind bridge: ef000000-ef0fffff [size=1M] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [40] Power Management version 3
	Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+
	Capabilities: [68] Express Downstream Port (Slot-), IntMsgNum 0
	Capabilities: [a4] Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Capabilities: [100] Vendor Specific Information: ID=ffff Rev=15 Len=008 <?>
	Capabilities: [fb4] Advanced Error Reporting
	Capabilities: [148] Virtual Channel
	Capabilities: [448] Vendor Specific Information: ID=0000 Rev=0 Len=0cc <?>
	Capabilities: [520] Access Control Services
	Capabilities: [950] Vendor Specific Information: ID=0001 Rev=0 Len=010 <?>
	Kernel driver in use: pcieport

04:01.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624] (rev bb) (prog-if 00 [Normal decode])
	Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Flags: bus master, fast devsel, latency 0, IRQ 33, NUMA node 0
	Bus: primary=04, secondary=06, subordinate=06, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: [disabled] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [40] Power Management version 3
	Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+
	Capabilities: [68] Express Downstream Port (Slot+), IntMsgNum 0
	Capabilities: [a4] Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Capabilities: [100] Vendor Specific Information: ID=ffff Rev=15 Len=008 <?>
	Capabilities: [fb4] Advanced Error Reporting
	Capabilities: [148] Virtual Channel
	Capabilities: [520] Access Control Services
	Capabilities: [950] Vendor Specific Information: ID=0001 Rev=0 Len=010 <?>
	Kernel driver in use: pcieport

04:04.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624] (rev bb) (prog-if 00 [Normal decode])
	Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Flags: bus master, fast devsel, latency 0, IRQ 34, NUMA node 0
	Bus: primary=04, secondary=07, subordinate=07, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: [disabled] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [40] Power Management version 3
	Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+
	Capabilities: [68] Express Downstream Port (Slot+), IntMsgNum 0
	Capabilities: [a4] Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Capabilities: [100] Vendor Specific Information: ID=ffff Rev=15 Len=008 <?>
	Capabilities: [fb4] Advanced Error Reporting
	Capabilities: [148] Virtual Channel
	Capabilities: [520] Access Control Services
	Capabilities: [950] Vendor Specific Information: ID=0001 Rev=0 Len=010 <?>
	Kernel driver in use: pcieport

04:05.0 PCI bridge [0604]: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624] (rev bb) (prog-if 00 [Normal decode])
	Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Flags: bus master, fast devsel, latency 0, IRQ 35, NUMA node 0
	Bus: primary=04, secondary=08, subordinate=08, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: [disabled] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [40] Power Management version 3
	Capabilities: [48] MSI: Enable+ Count=1/4 Maskable+ 64bit+
	Capabilities: [68] Express Downstream Port (Slot+), IntMsgNum 0
	Capabilities: [a4] Subsystem: PLX Technology, Inc. PEX 8624 24-lane, 6-Port PCI Express Gen 2 (5.0 GT/s) Switch [ExpressLane] [10b5:8624]
	Capabilities: [100] Vendor Specific Information: ID=ffff Rev=15 Len=008 <?>
	Capabilities: [fb4] Advanced Error Reporting
	Capabilities: [148] Virtual Channel
	Capabilities: [520] Access Control Services
	Capabilities: [950] Vendor Specific Information: ID=0001 Rev=0 Len=010 <?>
	Kernel driver in use: pcieport

05:00.0 RAID bus controller [0104]: Broadcom / LSI MegaRAID SAS 2108 [Liberator] [1000:0079] (rev 05) (prog-if 00 [Vendor specific])
	DeviceName: Integrated RAID                         
	Subsystem: Dell PERC H700 Integrated [1028:1f17]
	Flags: bus master, fast devsel, latency 0, IRQ 30, NUMA node 0
	I/O ports at fc00 [size=256]
	Memory at ef0fc000 (64-bit, non-prefetchable) [size=16K]
	Memory at ef040000 (64-bit, non-prefetchable) [size=256K]
	Expansion ROM at ef080000 [disabled] [size=256K]
	Capabilities: [50] Power Management version 3
	Capabilities: [68] Express Endpoint, IntMsgNum 0
	Capabilities: [d0] Vital Product Data
	Capabilities: [a8] MSI: Enable- Count=1/1 Maskable- 64bit+
	Capabilities: [c0] MSI-X: Enable+ Count=15 Masked-
	Capabilities: [100] Advanced Error Reporting
	Capabilities: [138] Power Budgeting <?>
	Kernel driver in use: megaraid_sas

0a:03.0 VGA compatible controller [0300]: Matrox Electronics Systems Ltd. MGA G200eW WPCM450 [102b:0532] (rev 0a) (prog-if 00 [VGA controller])
	DeviceName: Embedded Video                          
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, medium devsel, latency 64, IRQ 20, NUMA node 0
	Memory at e5800000 (32-bit, prefetchable) [size=8M]
	Memory at eeffc000 (32-bit, non-prefetchable) [size=16K]
	Memory at ee000000 (32-bit, non-prefetchable) [size=8M]
	Expansion ROM at 000c0000 [virtual] [disabled] [size=128K]
	Capabilities: [dc] Power Management version 1
	Kernel driver in use: mgag200

20:00.0 Host bridge [0600]: Advanced Micro Devices, Inc. [AMD/ATI] RD890 Northbridge only dual slot (2x8) PCI-e GFX Hydra part [1002:5a12] (rev 02)
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, NUMA node 6
	Capabilities: [f0] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [c4] HyperTransport: Slave or Primary Interface
	Capabilities: [40] HyperTransport: Retry Mode
	Capabilities: [54] HyperTransport: UnitID Clumping
	Capabilities: [9c] HyperTransport: #1a

20:02.0 PCI bridge [0604]: Advanced Micro Devices, Inc. [AMD/ATI] RD890/RD9x0/RX980 PCI to PCI bridge (PCI Express GFX port 0) [1002:5a16] (prog-if 00 [Normal decode])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, IRQ 37, NUMA node 6
	Bus: primary=20, secondary=21, subordinate=21, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: [disabled] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [50] Power Management version 3
	Capabilities: [58] Express Root Port (Slot+), IntMsgNum 0
	Capabilities: [a0] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [b0] Subsystem: Dell Device [1028:0444]
	Capabilities: [b8] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [100] Vendor Specific Information: ID=0001 Rev=1 Len=010 <?>
	Capabilities: [150] Advanced Error Reporting
	Capabilities: [190] Access Control Services
	Kernel driver in use: pcieport

20:03.0 PCI bridge [0604]: Advanced Micro Devices, Inc. [AMD/ATI] RD890/RD9x0 PCI to PCI bridge (PCI Express GFX port 1) [1002:5a17] (prog-if 00 [Normal decode])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, IRQ 38, NUMA node 6
	Bus: primary=20, secondary=22, subordinate=22, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: [disabled] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [50] Power Management version 3
	Capabilities: [58] Express Root Port (Slot+), IntMsgNum 0
	Capabilities: [a0] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [b0] Subsystem: Dell Device [1028:0444]
	Capabilities: [b8] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [100] Vendor Specific Information: ID=0001 Rev=1 Len=010 <?>
	Capabilities: [150] Advanced Error Reporting
	Capabilities: [190] Access Control Services
	Kernel driver in use: pcieport

20:0b.0 PCI bridge [0604]: Advanced Micro Devices, Inc. [AMD/ATI] RD890/RD990 PCI to PCI bridge (PCI Express GFX2 port 0) [1002:5a1f] (prog-if 00 [Normal decode])
	Subsystem: Dell Device [1028:0444]
	Flags: bus master, fast devsel, latency 0, IRQ 40, NUMA node 6
	Bus: primary=20, secondary=23, subordinate=23, sec-latency=0
	I/O behind bridge: [disabled] [32-bit]
	Memory behind bridge: [disabled] [32-bit]
	Prefetchable memory behind bridge: [disabled] [64-bit]
	Capabilities: [50] Power Management version 3
	Capabilities: [58] Express Root Port (Slot+), IntMsgNum 0
	Capabilities: [a0] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [b0] Subsystem: Dell Device [1028:0444]
	Capabilities: [b8] HyperTransport: MSI Mapping Enable+ Fixed+
	Capabilities: [100] Vendor Specific Information: ID=0001 Rev=1 Len=010 <?>
	Capabilities: [150] Advanced Error Reporting
	Capabilities: [190] Access Control Services
	Kernel driver in use: pcieport

Bus 001 Device 001: ID 1d6b:0001 Linux 6.8.0-136-generic ohci_hcd OHCI PCI host controller
Bus 002 Device 001: ID 1d6b:0002 Linux 6.8.0-136-generic ehci_hcd EHCI Host Controller
Bus 003 Device 001: ID 1d6b:0002 Linux 6.8.0-136-generic ehci_hcd EHCI Host Controller
Bus 003 Device 002: ID 0424:2514  
Bus 004 Device 001: ID 1d6b:0001 Linux 6.8.0-136-generic ohci_hcd OHCI PCI host controller
Bus 005 Device 001: ID 1d6b:0001 Linux 6.8.0-136-generic ohci_hcd OHCI PCI host controller
Bus 006 Device 001: ID 1d6b:0001 Linux 6.8.0-136-generic ohci_hcd OHCI PCI host controller